QuickStat-TC
Installation & Operation Manual
A
F
2
General Information
Use of this Manual
This manual covers the installation and operation of the Raychem
QuickStat-TC thermostat and must be used with the following document:
• QuickNet System Installation Manual (H57704)
Important: For the Tyco Thermal Controls warranty and agency
approvals to apply, the instructions included in this manual and product
packages must be followed.
Features
The QuickStat-TC is an electronic thermostat that must be used with the
Raychem QuickNet floor heating mats.
QuickStat-TC provides the following features:
• IntegratedClassA,Ground-FaultCircuitInterrupter(GFCI).
• Operatesat120V,208V,240V,60Hz.
• Switchesonyourheatingsystematpredeterminedtimesondifferent
days of the week.
• Offers4periodseachdaythatyoucansetatdifferenttemperatures.
• Comeswithapreprogrammedschedulethatissuitableformost
installations.However,youcancustomizethisprogramanytimeyou
wish.
• Allowsyoutoresetthethermostattofactorysettings.
• Changesthestarttimeofaheatingperiodautomaticallysothatthe
desired temperature is reached at the time that you set.
• Multipletemperaturecontroloptionssouserscancontrolthesystem
basedonfloortemperature(F),ambientairtemperature(A),orboth
(AF).
• On/Offswitchtoturnoffthermostatduringsummermonths.
Specifications
Approvals
Technical Data
Supplyvoltage 120V,208V,240V,60Hz
Maximumswitchingcurrent 15A
GFCI ClassA,5mAtriplevel
Ambientsetpointrange 40°Fto86°F(5°Cto30°C)
(A/AFmode)
Floorsetpointrange(Fmode) 40°Fto104°F(5°Cto40°C)
Floorlimitsetpointrange 40°Fto104°F(5°Cto40°C)
(AFmode)
Operatingtemperaturerange 32°Fto120°F(0°Cto50°C)
Storagetemperaturerange –4°Fto120°F(–20°Cto50°C)
A
C
B
E
D
Kit Contents
A 1 QuickStat-TCthermostat
B 2 Mountingscrews
C 1 Floortemperaturesensor15ft(4.6m)
D 5 Wire nuts
E 1 Screwdriver
400-115-052
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - QuickStat-TC

QuickStat-TCInstallation & Operation ManualAF2General InformationUse of this ManualThis manual covers the installation and operation of the Rayche

Page 2 - Installation

InstallationImportant: This thermostat must be installed according to all national and local electrical codes. The installation must be performed by

Page 3 - Ground-Fault Protection

Thermostat Controls and DisplayThe following figure shows the thermostat controls. The thermostat has three temperature control modes:• AFmode:(

Page 4 - Operating Modes

Programming The QuickStat-TC comes with a pre-programmed default schedule. The schedule consists of 4 periods per day which represents a typical week

Page 5 - Error Messages

Vacation Mode Inthismode,theQuickStat-TCissettotheVacationsetpoint temperatureandwilloverrideallprogramminguntilVacationmodeisdi

Page 6

QuickStat-TC Installation & Operation Manual6©2011TycoThermalControlsLLCH5851704/11Worldwide HeadquartersTyco Thermal Controls7433

Comments to this Manuals

No comments